Skip to main content

Chemtex manufactures RO Membrane Antiscalants for inhibition of scale fromation in RO feed water.


A membrane is a thin, film-like structure that separates two fluids. It acts as a selective barrier, allowing some particles or chemicals to pass through, but not others.
Various types of crystal growth activities occur on these membranes.RO feed water membranes are known to accumulate huge quantity of calcium sulfate scale which is very difficult to be removed.

ALKRO range of RO Antiscalants or Antifoulants are very effective for the prevention of these inorganic scales.Chemtex manufactures these RO Antiscalants or Antifoulants which surpasses the performance of other antiscalants (such as Perma-treat 191 etc. of Nalco) under stressed conditions of high pH. ALKRO antiscalants also effectively stabilizes metal ions to prevent fouling of the membrane.

Dosage:

ALKRO antiscalant or antifoulant chemical is normally fed continuously prior to the final cartridge filter. It should be injected by chemical dosing pump from a dilution tank or directly from the drum to the feed water line. The amount of antiscalant or antifoulant required to inhibit scale formation depends on the quality of feed water and size of the membrane system.

ALKRO R.O. MEMBRANE ANTISCALANTS are available in low and high pH that enables to adjust the pH of permeate water without adding acid and alkali.

The major benefits of these chemicals are
  • Scaling is prevented.
  • Reduced downtime required for periodic cleaning of membranes
  • Enhances the quality of permeate water
  • Very easily used & handled.
  • Maintains flow rate close to design and saves power.
  • Increase in productivity. 

Contact Us

Chemtex Speciality Limited
Regd. Office :33 Brabourne Road, Kolkata 700 001,West Bengal, India
Phone : +(91)-(33)-7111-1111 / 7111-1112 Fax : +(91)-(33)-7111-1117
Mobile : +(91)-896-111-1111

RO Membrane Antiscalant

 



Popular posts from this blog

RO Antiscalant

Reverse Osmosis serves as one of the most critical processes that are involved in the process water treatment to clean water, utilized in various industrial process applications. Reverse Osmosis can be regarded as the process wherein semi-permeable membranes help in separating purified water from contaminated water. It occurs when a pressure is applied to the concentrated side of the membrane resulting in forcing purified water to the dilute side. Reverse Osmosis is very efficient for the treatment of brackish, surface and ground water for both large and small flow applications. Some examples of industries that use RO water include boiler feed water, food and beverage, pharmaceutical, metal finishing and semiconductor manufacturing to mention a few. The overall performance of a reverse osmosis system relies on various factors like feed water quality, membrane type, flow control, temperature and pressure. Systems must be well maintained for ensuring effective performance with any

Hybrid Organic Acid Technology (HOAT) Coolant

Optimal use of machines is directly proportional to its engine performance. What an engine does is it converts the supplied energy into its mechanical form, driving the machine to work. Engines require one-third of total heat that is generated during conversion and the rest of the heat is needed to be evacuated from the combustion chamber which would otherwise lead to engine failure. Earlier, water was preferred as an ideal coolant for quite a period of time but the problem started to arise when the temperature would become extremely high or low, to be precise temperature more than 100 ° C and below 0°C. To get rid of this problem, coolants were formulated. Coolants are categorized chemicals that increases the boiling point of the fluid and decreases the freezing point of the fluid to make it suitable for use in extreme heat and freezing conditions. Coolants are a proportionate mixture of antifreeze and solvent, mainly glycol and water. Ideally utilized as a preventive in

Antiscalant Chemical for RO Plant

  Reverse Osmosis System is a revolutionary invention to treat water and provide an effective solution for purifying water in various applications. The performance of RO can be ensured by the formation of scale and deposits on the membranes, leading to reduced efficiency and increased operational costs.   To prevent this issue, antiscalant chemicals play an important role in reducing the formation of scale and maintaining optimal RO Plant performance. Reverse Osmosis is widely used in various industries to treat water and to remove impurities such as salts, minerals, and other contaminants. The dense, thin, and semi-permeable layer allows water molecules to pass through while rejecting dissolved solids, and other impurities such as salts, minerals, and other contaminants. But the major issue that surfaces in such systems is the formation of scales due to the build-up of dissolved minerals and salts on the surface of the RO Membrane. RO Antiscalant Chemicals – Cost-effective Soluti