Chemtex manufactures RO Membrane Antiscalants for inhibition of scale fromation in RO feed water.


A membrane is a thin, film-like structure that separates two fluids. It acts as a selective barrier, allowing some particles or chemicals to pass through, but not others.
Various types of crystal growth activities occur on these membranes.RO feed water membranes are known to accumulate huge quantity of calcium sulfate scale which is very difficult to be removed.

ALKRO range of RO Antiscalants or Antifoulants are very effective for the prevention of these inorganic scales.Chemtex manufactures these RO Antiscalants or Antifoulants which surpasses the performance of other antiscalants (such as Perma-treat 191 etc. of Nalco) under stressed conditions of high pH. ALKRO antiscalants also effectively stabilizes metal ions to prevent fouling of the membrane.

Dosage:

ALKRO antiscalant or antifoulant chemical is normally fed continuously prior to the final cartridge filter. It should be injected by chemical dosing pump from a dilution tank or directly from the drum to the feed water line. The amount of antiscalant or antifoulant required to inhibit scale formation depends on the quality of feed water and size of the membrane system.

ALKRO R.O. MEMBRANE ANTISCALANTS are available in low and high pH that enables to adjust the pH of permeate water without adding acid and alkali.

The major benefits of these chemicals are
  • Scaling is prevented.
  • Reduced downtime required for periodic cleaning of membranes
  • Enhances the quality of permeate water
  • Very easily used & handled.
  • Maintains flow rate close to design and saves power.
  • Increase in productivity. 

Contact Us

Chemtex Speciality Limited
Regd. Office :33 Brabourne Road, Kolkata 700 001,West Bengal, India
Phone : +(91)-(33)-7111-1111 / 7111-1112 Fax : +(91)-(33)-7111-1117
Mobile : +(91)-896-111-1111

RO Membrane Antiscalant

 



Popular posts from this blog

TONO FROST 593: The Ultimate NSF-Certified Solution for Food & Beverage Heat Transfer

In the world of food and beverage processing, maintaining thermal efficiency, ensuring product safety, and minimizing operational downtime are all non-negotiable demands. Whether it’s for cold storage, chilling equipment, pasteurization lines, or fermentation control, the choice of heat transfer fluid can significantly impact both performance and compliance. TONO FROST 593 , developed by Chemtex, is an NSF HT1-certified inhibited propylene glycol solution engineered to meet the highest standards of safety, performance, and efficiency in food-grade environments. What is TONO FROST 593 ? TONO FROST 593 is a blend of food-grade propylene glycol and a corrosion inhibitor package designed to provide: Long-lasting protection against rust, scale, and corrosion Stable thermal conductivity Wide temperature operability Food safety compliance for indirect contact In a market flooded with products, NSF certification stands as illumination of reliability and trust. Unlike many pre-inhibited glyco...

Acid Coil Cleaner leaves the aluminum surface clean and shining bright

Improper refrigerant levels, dirty coils, and worn out compressors or condensers can result in inefficient performance of air conditioning system. An inefficient system tends to force the compressor to work harder than is required decreasing its life span and thereby leading to higher energy bills. The primary energy required in operating an air conditioning system comes from the compression of refrigerant. The hotter the compressor receives the processed refrigerant, the more energy is necessary to force it through the condenser. The refrigerant needs to become cold enough to absorb more heat from the process, therefore an external chiller such as an open evaporative condenser or air blast unit is required. It is crucial for effective air-conditioning operation that the condenser is able to easily reject heat through the cooling airflow and the heat exchanger coils. Energy consumption builds up as the refrigerant vapor pressure increases, where the refrigerant is not sufficien...

Hybrid Organic Acid Technology (HOAT) Coolant

Optimal use of machines is directly proportional to its engine performance. What an engine does is it converts the supplied energy into its mechanical form, driving the machine to work. Engines require one-third of total heat that is generated during conversion and the rest of the heat is needed to be evacuated from the combustion chamber which would otherwise lead to engine failure. Earlier, water was preferred as an ideal coolant for quite a period of time but the problem started to arise when the temperature would become extremely high or low, to be precise temperature more than 100 ° C and below 0°C. To get rid of this problem, coolants were formulated. Coolants are categorized chemicals that increases the boiling point of the fluid and decreases the freezing point of the fluid to make it suitable for use in extreme heat and freezing conditions. Coolants are a proportionate mixture of antifreeze and solvent, mainly glycol and water. Ideally utilized as a preventive in...