Skip to main content

Optimize Your Boiler, Chiller, and Condenser Performance with powerful Descaling Chemicals

 Industrial equipment like boilers, chillers, and condensers are important for any commercial system. To prevent heat exchangers, chillers, and condensers from scaling is important to get optimal performance. However, over time, these essential components can suffer from a build-up of scale and mineral deposits, leading to reduced performance, increased energy consumption, and even equipment failure.

The numerous components enter this equipment with feed water as feed water contains dissolved solids and impurities, salts, etc. If it gets overlooked, the scale gets hardened due to continuous heating of the boiler.

Characteristics of most common deposits

•Carbonate deposits, large granules, and porous forms dense and uniform pitting and scaling over the surface

•Sulphate deposits, crystalline, fine particles but a bit harder and denser than a regular carbonate deposit

•Hard and not so easy to remove silica deposits, extremely small, forms a dense and impervious scaling

•Iron deposits

How does Descaling chemical help?

Descaling chemicals act as powerful agents that effectively removes scale and mineral deposits from the internal surfaces of boilers, chillers, and condensers system. Using these descaling chemicals regularly ensures the protection of the system metallurgy, providing a long service life for the boiler system. This formulation eliminates mineral scales, metal oxides, sludge, and other deposition, prevents corrosion caused by oxidation, and maintains pH, these benefits not only optimize operational performance but also contribute to a more sustainable and cost-effective operation. 



Selecting the most suitable one for your specific requirement is important for your system. This formulation not only optimizes operational performance but also contributes to a more sustainable and cost-effective solution.     

With numerous descaling chemical options available in the market, selecting the most suitable one for your specific application can be daunting. We will provide insights into key factors to consider when choosing a descaling chemical, such as compatibility with different materials, environmental considerations, and industry regulations. This information will help you make an informed decision and select the most effective product for your system. The need for descaling chemical cleaning during the life of equipment has become a recognized fact & should be accepted as a maintenance practice. 

We, Chemtex Speciality Limited specialize in providing high-quality descaling chemicals for boilers, chillers, and condensers. Our range of descaling chemicals is specifically formulated to address to meet your specific requirement.

Chemclean 05 – Sulfamic acid-based descaling chemical to prevent fouling in Boiler

Chemclean 06 – Sodium hydroxide and Phosphate based descaling chemical for removing silica & organic deposits from the water side of the boiler. 

Chemclean 01 – Sodium Hydroxide and Phosphate based descaling chemical effectively removes organic foulant, oil, and grease from the boiler.

Alstascale OD40/DS10 -Online desclant or rust remover for new or old CHW line carrying chiller water, glycol antifreeze, or calcium chloride brine.

Alstascale DS85 – Heavy-duty liquid descaling formulation for hard water scales with high silica or silicate deposits.

Visit our website to explore our range of descaling chemicals that can help optimize the performance and extend the lifespan of your equipment.

https://www.chemtexltd.com/products-and-solutions/cleaning-and-disinfectant-chemicals/speciality-industrial-cleaning/

Popular posts from this blog

RO Antiscalant

Reverse Osmosis serves as one of the most critical processes that are involved in the process water treatment to clean water, utilized in various industrial process applications. Reverse Osmosis can be regarded as the process wherein semi-permeable membranes help in separating purified water from contaminated water. It occurs when a pressure is applied to the concentrated side of the membrane resulting in forcing purified water to the dilute side. Reverse Osmosis is very efficient for the treatment of brackish, surface and ground water for both large and small flow applications. Some examples of industries that use RO water include boiler feed water, food and beverage, pharmaceutical, metal finishing and semiconductor manufacturing to mention a few. The overall performance of a reverse osmosis system relies on various factors like feed water quality, membrane type, flow control, temperature and pressure. Systems must be well maintained for ensuring effective performance with any

Hybrid Organic Acid Technology (HOAT) Coolant

Optimal use of machines is directly proportional to its engine performance. What an engine does is it converts the supplied energy into its mechanical form, driving the machine to work. Engines require one-third of total heat that is generated during conversion and the rest of the heat is needed to be evacuated from the combustion chamber which would otherwise lead to engine failure. Earlier, water was preferred as an ideal coolant for quite a period of time but the problem started to arise when the temperature would become extremely high or low, to be precise temperature more than 100 ° C and below 0°C. To get rid of this problem, coolants were formulated. Coolants are categorized chemicals that increases the boiling point of the fluid and decreases the freezing point of the fluid to make it suitable for use in extreme heat and freezing conditions. Coolants are a proportionate mixture of antifreeze and solvent, mainly glycol and water. Ideally utilized as a preventive in

Antiscalant Chemical for RO Plant

  Reverse Osmosis System is a revolutionary invention to treat water and provide an effective solution for purifying water in various applications. The performance of RO can be ensured by the formation of scale and deposits on the membranes, leading to reduced efficiency and increased operational costs.   To prevent this issue, antiscalant chemicals play an important role in reducing the formation of scale and maintaining optimal RO Plant performance. Reverse Osmosis is widely used in various industries to treat water and to remove impurities such as salts, minerals, and other contaminants. The dense, thin, and semi-permeable layer allows water molecules to pass through while rejecting dissolved solids, and other impurities such as salts, minerals, and other contaminants. But the major issue that surfaces in such systems is the formation of scales due to the build-up of dissolved minerals and salts on the surface of the RO Membrane. RO Antiscalant Chemicals – Cost-effective Soluti